(1) HN gas mixing control
the actual flow rate gas H2 and N2 gas each will be measured by measuring the holes flow, and will be managed so that it would be provided per cent H2.The contents of the gas (H2 in HN gas will be monitored by the analyzer H2, after, as well as mixes. Emergency N2, that gas will be delivered a separate line.Lord (2) gas flow control HN
HN gas will be supplied in the oven RTHS, RTSS, GJS. In the normal mode of operation the standing volume of gas HN will be supplied in the oven.
when oven-pressure comes down HN gas flow will increase. When the line is stopped,Set the value to H2% will be reduced automatically. Lord (3) the system cleaning ovens
after oven is open for service, etc. ,Purge the initial oven to heat-will be carried out with the gas N2 for a few hours. At this time, the content of the O2 in the oven will be approximately 0.5 %.Then the initial purging will be changed to normal cleaning and microwave starts to heat up. As a general rule, the contents of the O2 in the oven has reduced sufficiently (0.1 %) when the gas supply classic mechanicsAt this time, the content of the O2 in the oven can be controlled by starting the analyzer O2.Lord (4) H2, O2 and the dew point analyzers
o2 ppm, H2 %, dew point will be measured in RTHS, RTSS, RAS, RCS,The heating section and TDS at the outlet HN mixing. These signals will be sent to DCS oven for monitoring. The atmosphere gas at each point has always sucked in by sampling pump and is measured in series with the valve,Crossed in order.